Control Partitions

Control Partitions

You can set arming mode and clear alarms for partitions of the security control panel via the Mobile Client. Partition, which is an independent control system of a security control panel, allows you to batch arm/disarm all zones in it. If the security control panel has multiple partitions, you have multiple independent systems for arming or disarming.

On the device list page, tap the security control panel and then log in to the device (if required) to enter the Partition page and then control the partition. You can swipe to the left or right to switch partitions.

Operations for a Single Partition

  • Away: When all the people in the detection area leave, turn on the Away mode to turn on all zones in the partition after the defined dwell time.

  • Stay: When the people stays inside the detection area, turn on the Stay mode to turn on all the perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in the balcony). At the meantime, the detectors inside the detection area are bypassed (such as PIR detectors). People can move inside the area and alarm will not be triggered.
  • Disarm: In Disarm mode, all the zones in the partition will not trigger alarm, no matter alarm events happen or not.

  • Clear Alarm: Clear all the alarms triggered by the zones of the partition.

Operations for All Partitions

  • Away: When all the people in the detection area leave, turn on the Away mode to turn on all zones in all partitions after the defined dwell time.

  • Stay: When the people stays inside the detection area, turn on the Stay mode to turn on all the perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in the balcony) set in all the zones of all partitions. At the meantime, the detectors inside the detection area are bypassed (such as PIR detectors). People can move inside the area and alarm will not be triggered.
  • Disarm: In Disarm mode, all the zones of all partitions will not trigger alarm, no matter alarm events happen or not.

  • Clear Alarm: Clear all the alarms triggered by the all the zones of all the partitions.